导航:首页 > 防爆电器 > 燃气锅炉房电气防爆

燃气锅炉房电气防爆

发布时间:2021-01-19 12:28:58

❶ 燃气锅炉房电气必须防爆吗

室外燃气锅炉电气设备不用考虑防爆。只有在燃气分配站区域的电气设备要考虑防爆。

❷ 燃气锅炉房锅炉间电气设备要求防爆吗

一般情况下,燃气锅炉房的电气设备是没有防爆要求的。按要求做好管道的防静电接地就足够了。

❸ 求一位大侠帮忙把论文翻译成英文~100分 谢谢 燃气锅炉房的电气防爆设计 摘 要:通过分析燃气锅炉房事故原

2 accident reason analysis

Analysis of gas boiler room the cause of the accident, there are two possible: boiler ontology explosion, boiler room to explode gas explosion concentration and explosions.

Boiler blast furnace body, because be in, or flue gas mixture in explosive existence, when achieved by fire or explosion limit, boiler heat ignites causing accidents in itself. This point and the national norm of building fire system that conform to the relevant provisions. The actual current boiler proct has considered safe proction measures to avoid it. Qualified gas boiler itself has the explosion-proof process design, such as burner in abnormal situation automatic stop, self-control device also stop output fuel, Gas boiler combustion system higher automatization, including the gas pressure is high, low limit alarm protection, when the control logic where step does not meet the conditions set start corresponding interlock protection.

Avoid the boiler exploded possibility, but still ontology exist above another possibility, can avoid? How to avoid it?

Three measures

In fact in design, according to the boiler design code "and" automatic fire alarm system design code "GB50116-1998 etc standard, we have taken the following measures:

Natural gas pipelines valves, meter, may occur gas leak place, boiler room may proce gas storage proct area [relative density 0.8, it is to be in commonly roof area in these areas], all equipped with combustible gas concentration measurement alarm device, according to combustible gas concentration situation give out sound and light alarm signal and start exhaust fan, when leakage accident concentrations reach explosion limit of the lower limit 50% [this value for reference only], but also immediately close natural air intake ct total intake solenoid valves.

In the boiler room and a natural gas pipeline in and out of the room, the incident, but also with the smoke exhaust fan combustible gas alarm interlocking (start).

Electrical, instrument by cable selection TongXin, not less than 1.5 mm2 minimum section.

Gas radiation tube tube top or the nearby, the lightning rod should be installed above the pipe jacking tip should be not less than 3m, and its scope of protection tube top above not less than 1-m.

Gas pipeline should be static grounding device that, when pipeline as metal materials, and lightning protection or electrical engineering protective grounding wire connected, the measured resistance R more than 4 Ω. In pipe joints, such as the bend, flange, valve and pipe with good place cannot metal contact, also with metal soft line will be both ends jumper.

In the boiler room and a natural gas pipeline in and out of the room door, window take pressure measures.

According to the explosion and fire dangerous environment electrical device design specification "the laws 2.2.2 bar, accord with one of the following conditions may, when the explosion danger area: devin in item 3, in the process of proction use fire equipment near, A combination of these several measures can clearly, electrical equipment selection for the explosion.

At the same time according to the explosion and fire dangerous environment electrical device design specification "the laws 2.2.2 bar, accord with one of the following conditions may, when the explosion danger area devin: the first 2 items, and the highest possible flammable explosive chroma does not exceed 10% of the lower limit, Close air intake ct natural total intake solenoid valves, concentration exceed 10% of the lower limit explosion limit, boiler room near the roof area are gas storage proct area, so lighting lamps and lanterns and switch choosing is explosion-proof type.

4 conclusion

In gas boiler room electrical design, lighting choose explosion-proof lamps, other part adopts the explosion-proof type.

references

[1] boiler design standard. GB50041-1992.

[2] explosion and fire dangerous environment electrical device design standard. GB50058-1992.

[3] the code for fire protection design of buildings. GB50016-2006.

[4] automatic fire alarm system design standard. GB50116-1998.

阅读全文

与燃气锅炉房电气防爆相关的资料

热点内容
西建设机械有限公司怎么样 浏览:943
电梯停电自动救援装置接线 浏览:282
铸造件有气孔用什么腻子粉 浏览:954
供暖阀门钥匙怎么安装 浏览:351
机械表运作是靠什么 浏览:476
soy是什么阀门商标 浏览:534
容声冰箱不制冷也不制冻怎么办 浏览:658
汽修工具箱整理方案 浏览:663
电机外壳铝合金铸造怎么选 浏览:261
海尔空调制冷标上面是什么标 浏览:82
无锡哪里可以安装etc设备 浏览:789
机械租赁货物名称怎么开 浏览:641
机械革命笔记本换个键盘多少钱 浏览:997
苏州鑫达机械有限公司怎么样 浏览:210
自动并列装置中频率差测量 浏览:352
口罩上的小阀门是什么 浏览:742
自动扶梯防滑装置安装规范 浏览:465
什么烃化物可以做制冷剂 浏览:253
汕头博世电动工具批发 浏览:894
供热暖气开阀门钥匙 浏览:914